MINT — Validation Report¶
Every correlation, its validation status, and the evidence.
Updated 6 Aug 2026 · 436 tests · branch joleks
Nobody else in this market publishes this. That is the point — this file becomes the public
/validationpage. An engineer who can see exactly how far we have proven each model will trust the ones we have proven and treat the rest with the caution they deserve.
Validation levels¶
| Level | Meaning |
|---|---|
| 🟢 VALIDATED | Reproduces a published worked example to the precision the source prints |
| 🔵 DIAGNOSED | Deviates from a published example, and the deviation is isolated to a named cause with evidence |
| 🟡 BEHAVIOUR | No published reference checked yet. Tested for physical correctness — monotonicity, limits, inverses, stability |
| ⚪ UNTESTED | Implemented, not yet exercised |
Honest framing: 🟡 is not "probably fine." Behaviour tests caught eleven real bugs in this codebase, including a factor-of-10⁶ unit error and a correlation that inflated its output 2.7×. But they cannot tell you whether Standing's constants are right. Only 🟢 can.
Summary¶
| Count | |
|---|---|
| 🟢 Validated against published numbers | 7 |
| 🔵 Diagnosed | 1 |
| 🟡 Behaviour-tested | 48 |
| ⚪ Untested | 0 |
Inflow — oil¶
| Model | Level | Evidence | Accuracy |
|---|---|---|---|
| Vogel | 🟢 | Guo 2nd ed, Ex 3.6 | qmax 978 stb/day exact · all 7 published curve points within 5 psi |
| Fetkovich | 🟢 | Guo 2nd ed, Ex 3.6 | all 7 points within 2 psi · AOF 900 stb/day exact |
| Fetkovich multi-rate fit | 🟢 | Guo 2nd ed, Ex 3.6 | recovers published n = 1.0 and C = 0.0001 from raw test points, rel 1e-3 |
| Composite (linear + Vogel) | 🟢 | Guo 2nd ed, Ex 3.5 Well B | J* = 0.3156 stb/day-psi, rel 1e-3 |
| Productivity Index | 🟡 | — | straight line, endpoints, monotonic |
| Jones (Darcy + non-Darcy) | 🟡 | — | round-trips, endpoints, AOF from quadratic root |
| Darcy PSS / steady | 🟡 | — | J scales linearly with kh; skin reduces, stimulation increases |
| Darcy transient | 🟡 | — | rejects times too short for infinite-acting flow |
| Joshi horizontal | 🟡 | — | geometry term positive, physical J |
| Babu-Odeh horizontal | 🟡 | — | physical J, rejects bad drainage geometry |
| Jones multi-rate fit | 🟡 | — | recovers known a, b to 1e-6 from synthetic points |
| Vogel AOF least-squares fit | 🟡 | — | fits through origin |
Inflow — gas¶
| Model | Level | Evidence | Accuracy |
|---|---|---|---|
| Back Pressure (Rawlins-Schellhardt) | 🟡 | — | round-trips exactly; n=0.5 gives lower AOF than n=1 |
| Back Pressure (pseudo-pressure) | 🟡 | — | endpoints, monotonic |
| Forchheimer / LIT (p²) | 🟡 | — | round-trips exactly; a=0 reduces to pure Darcy |
| Forchheimer (pseudo-pressure) | 🟡 | — | endpoints |
| Darcy gas | 🟡 | — | AOF scales exactly ×10 with k ×10; skin ordering correct |
| Modified Isochronal | 🟡 | — | reproduces the stabilised anchor point to 1e-6 |
| C&n multi-rate fit | 🟡 | — | recovers known C, n to 1e-6 |
| Forchheimer multi-rate fit | 🟡 | — | recovers known a, b to 1e-6 |
| Pseudo-pressure m(p) | 🟡 | — | monotonic, inverts to 1e-3, super-linear as expected |
Outflow — VLP¶
| Model | Level | Evidence | Accuracy |
|---|---|---|---|
| Poettmann-Carpenter | 🟢 | Guo 2nd ed, Ex 4.2 | BHP 1701 vs 1699 psia — 0.1% · 14 of 14 printed intermediates within 2% |
| Static gas column | 🟢 | average-T-and-z method (Guo Ch.4, analytic) | traverse at vanishing gas rate reproduces the closed form to 0.2% — correlation-independent anchor for the whole gas path |
| Guo-Ghalambor (four-phase) | 🟢 | Guo 2nd ed, Ex 4.4 | pwf 1658 vs 1682 psia (1.4%) — within the book's own self-disagreement: its printed groups through its printed equation give 1660. Found a misprint in the 2nd ed (cosθ placement in Eqs 4.33-34); the spreadsheet's printed M, N back-solve exactly to the 2005 formulation, which we implement. a, b, c, e match to print precision |
| Sagar-Doty-Schmidt thermal | 🔵 | SPE 19702 (no worked example printed) | closed form matches RK4 integration of the paper's own ODE to 1e-4 K over 4000 steps; wellhead T rises with rate; gas annulus insulates; F_c inside the paper's Fig. 4 band at database-average conditions |
| Hagedorn-Brown | 🔵 | Guo 2nd ed, Ex 4.6 | traverse +9.4% on the raw run. Cause isolated: oil density (ours 49.6 vs book-implied 45.4 lb/ft³). Pin density, change nothing else → 3188 vs 3157 psia, 1.0%. Hydraulics correct; residual is PVT. |
| Beggs-Brill (+ Payne) | 🟡 | — | flow patterns identified, holdup ≥ no-slip, inclination sign correct, stable across 16 velocity combinations |
| Fancher-Brown | 🟡 | — | is the lower bound on every other correlation, as designed |
| Pressure traverse integrator | 🟢 | via P-C and H-B above | step refinement converges <2% from 100 m → 10 m |
⚠️ Note on Ex 4.6: at GLR 75 scf/bbl the bubble point is 340 psia, so the well is undersaturated over 97% of its length. That example is a hydrostatic-column test, not a real multiphase test. A high-GOR published example is needed before Hagedorn-Brown can go 🟢.
PVT — oil¶
| Correlation | Level | Evidence |
|---|---|---|
| Standing Rs / Pb / Bo | 🟡 | Rs↔Pb mutual inverses to 1e-3; Rs = 78.42 scf/stb matched Guo Ex 4.2 exactly inside the P-C validation |
| Glaso Rs / Pb / Bo | 🟡 | mutual inverses |
| Petrosky-Farshad Rs / Pb / Bo | 🟡 | mutual inverses (sign bug found and fixed here) |
| Vasquez-Beggs Rs / Pb / Bo | 🟡 | mutual inverses; separator correction changes result; API-30 branch switch verified |
| Al-Marhoun Rs / Pb | 🟡 | mutual inverses |
| Lasater Pb | 🟡 | physical range; zero GOR → zero Pb |
| Beal / Beggs-Robinson / Glaso / Egbogah dead viscosity | 🟡 | falls with T, rises as oil gets heavier, plausible range |
| Chew-Connally / Beggs-Robinson saturated viscosity | 🟡 | dissolved gas thins the oil (sign check) |
| Vasquez-Beggs undersaturated viscosity | 🟡 | rises above Pb, continuous at Pb |
| Vasquez-Beggs / Petrosky-Farshad / McCain Co | 🟡 | 1e-7–1e-4 /psi, falls with pressure |
| Oil density (material balance) | 🔵 | 9% above Guo Ex 4.6's implied value — under investigation, see H-B row |
PVT — gas & water¶
| Correlation | Level | Evidence |
|---|---|---|
| Hall-Yarborough z | 🟡 | residual driven to <1e-8 at the root across 30 (Tpr, Ppr) pairs; agrees with DAK within 1.6% |
| Dranchuk-Abou-Kassem z | 🟡 | independent cross-check on Hall-Yarborough |
| Sutton pseudo-criticals | 🟡 | physical range for natural gas |
| Wichert-Aziz sour correction | 🟡 | lowers Tpc and Ppc; exact no-op for sweet gas |
| Lee-Gonzalez-Eakin viscosity | 🟡 | 0.005–0.10 cP range |
| McCain Bw / μw / Rsw / Cw / density | 🟡 | all monotonic in the right direction; Fahrenheit-vs-Rankine bug found and fixed here |
System¶
| Component | Level | Evidence |
|---|---|---|
| Nodal solve | 🟢 | closed-form analytic case to 1e-9 · axis-independence: identical answer at 12 and 1000 grid points · verified on a real U-shaped VLP producing 3 intersections, correct stable one selected |
| Units layer | 🟢 | round-trips every quantity through every display system to 1e-12 · affine temperature and gauge/absolute pressure explicitly tested |
| Applicability envelopes | 🟢 | published ranges asserted against the literature values (e.g. Vasquez-Beggs 15.3–59.3 °API) |
New since last update — behaviour-tested¶
| Module | Models | Level |
|---|---|---|
| Matching engine | shared regression, VLP α/β, IPR productivity | 🟡 recovers known multipliers to 1e-6 from synthetic data |
| PVT lab matching | PROSPER's Regression function, correlation ranking | 🟡 recovers 1.12/1.04 multipliers exactly; ranking identifies the fitting correlation at <1e-6% |
| Skin | Karakas-Tariq, MacLeod, Brons-Marting, Cinco-Ley, gravel pack | 🟡 signs, limits and monotonicity pinned |
| VLP | Duns-Ros, Orkiszewski, Gray | 🟡 all above the no-slip floor, stable over a 96-point sweep |
Artificial Lift - continuous gas lift¶
| Component | Level | Evidence |
|---|---|---|
| Injection requirement, Eqs. 13.1-13.2 | DIAGNOSED | Production Engineering Ex. 13.1: interpolation gives 3,072 scf/STB and injection GLR 2,772 scf/STB. The book prints (2,772)(632) = 1,720,000; correct multiplication is 1,751,904 scf/d. MINT returns the equation result and documents the source error. |
| Injection-depth-aware VLP | BEHAVIOUR | bounded traverses recombine to the unchanged full-well answer; injected free gas affects only the tubing above the mandrel; existing VLP regression suite remains green |
| Performance/economic sweep | BEHAVIOUR | finds interior max-rate point on a rolling synthetic curve; economic optimum can sit below max-rate optimum; failed cases remain visible; real PVT-to-VLP-to-nodal test lifts a dead well to a stable point |
| Ex. 13.1 full operating point | DIAGNOSED | not reproducible as printed: its Vogel IPR gives 1,391 psia at injection depth at 632 STB/d, not the reported 698 psia; three referenced spreadsheets and their PVT/thermal inputs are absent |
| Valve spacing, Eqs. 13.49/13.53 | DIAGNOSED | Production Engineering Ex. 13.5 is internally inconsistent: its printed inputs give 2,238.91 ft then 3,759.05 ft, not 2,245 then 3,004 ft. The independent Production Systems Eq. 11.22 / Ex. 11.5 fixture reproduces all six depths within 2 ft. |
| Unbalanced-bellows mechanics | PUBLISHED EXAMPLE | Production Engineering Ex. 13.7 valve 1: 817 psig dome pressure at depth, 683 psig at 60 °F after temperature/z correction, and 918 psig test-rack opening pressure reproduced. |
| Unloading sequence | BEHAVIOUR | opening/closing hysteresis is stateful; failed transfer and still-open shallower valves are explicit diagnostics |
| Existing mandrels | ALGORITHMIC | ordered one-to-one assignment globally minimizes total absolute depth error under the caller's tolerance; infeasible hardware returns no misleading partial design |
| Valve port capacity | PUBLISHED EXAMPLE | Production Engineering Eq. 13.56 / Ex. 13.6 reproduces 0.1684 in² required area and 0.4631 in diameter; ideal-gas critical ratio and choked-capacity plateau are independently pinned |
| Port catalog selection | ALGORITHMIC | smallest adequate caller-supplied diameter is selected; undersized ports, area margin, supported gas rate, and infeasible catalogs are tested explicitly; no vendor catalog is embedded |
| API RP 11V2 tested-Cv/Xt flow | PUBLISHED EXAMPLE | full standard Appendix A reproduced at 496 MSCF/day, including Fk·Xt choking and expansion factor |
| API RP 11V2 probe analysis | PUBLISHED EXAMPLE | Appendix C reproduced at 606.71 psi/in bellows load rate and 0.098 in maximum effective stem travel |
| API RP 11V2 physical test conformance | EXTERNAL EVIDENCE | calculations are implemented; apparatus geometry, calibration, accuracy, procedure, facility/operator, specimen drawings, and Data Forms 1-4 must come from the executing laboratory |
The twelve bugs these tests caught¶
| # | Where | What | Severity |
|---|---|---|---|
| 1 | legacy pdt.py |
Nodal compared IPR and VLP by row index on different axes | operating point was never the intersection |
| 2 | legacy gas.py |
Hall-Yarborough Newton residual computed outside the loop | never converged, one step only |
| 3 | legacy gas.py |
Route '/ calculate_viscosity' — leading space |
404 since written |
| 4 | legacy fwater.py |
Rankine passed where McCain specifies Fahrenheit | every water number wrong |
| 5 | legacy gas.py |
Module-level lists appended per request | results drifted between users |
| 6 | pvt/oil.py |
rs_petrosky_farshad used −X where the inverse needs +X |
Rs inflated 2.7× |
| 7 | ipr/gas_models.py |
m(p) SI→field divided instead of multiplied | factor of 10⁶ on every gas rate |
| 8 | ipr/pseudo_pressure.py |
Table missing the origin | spurious floor under every AOF |
| 9 | ipr/oil_models.py |
Rejected n = 1.0000000000000084 from a clean fit |
valid model refused |
| 10 | vlp/poettmann_carpenter.py |
Mass on a per-stb-liquid basis where Guo works per stb-oil | column 25% light |
| 11 | vlp/poettmann_carpenter.py |
Free-gas volume dropped the z-factor; Moody/Fanning friction confusion | 5% and 4× respectively |
| 12 | vlp/correlations.py |
Duns-Ros slip inversion took (vm − v_s) where the root needs (v_s − vm) |
returned the gas complement, holdup saturated at 1.0 with gas flowing |
What would move things to 🟢¶
- High-GOR VLP example → Hagedorn-Brown and Beggs-Brill
- Guo Ch.2 PVT tables → Standing, Vasquez-Beggs, Glaso and the gas correlations
- Guo Ex 6.2 nodal → whole-chain validation
- Resolve the 9% oil density gap → unblocks every VLP number
- TUFFP data bank → the 1,712-case multiphase bank; the one validation asset money can buy
What we do not claim¶
- ±15% on multiphase ΔP is state of the art. Published comparison studies put single-correlation MAPE between 12.7% and 57.5% depending on fluid. Anyone claiming better across a broad dataset is overfitting.
- Correlations outside their published envelope are extrapolations. MINT flags this at the point of use and names the offending variable — see the applicability badges.
- No number here was tuned against PROSPER, whitson, or any competitor's output. Validation is against published worked examples and, in future, field data.
Blocked on source quality — Petalas-Aziz (1998)¶
Not implemented. The paper in books/petalas1998.pdf is a scan whose OCR
has destroyed the exponents in the friction correlations.
Two independent extractors (pypdf, pdfplumber) return the same damage:
Eq. 10 f, = 0.452fF' <- exponent on f_sL lost
Eq. 12 f; = (0.004 + 0.5 x 10m6R e,)Fry <- exponent on Fr_L lost
Those exponents are not decoration; they are the correlation. The structure is readable (dispersed-bubble bounds via Gregory slug holdup, stratified momentum balance with Taitel-Dukler geometry, Kelvin-Helmholtz stability, Barnea's steep-downhill annular transition), but a mechanistic model assembled with guessed exponents returns plausible numbers that are wrong — the exact failure mode the "never implement from memory" rule exists to prevent, and which has caught more than twenty bugs in this repo including a misprint in Guo's own textbook.
To unblock: a text-layer copy of Petalas, N. & Aziz, K., "A Mechanistic
Model for Multiphase Flow in Pipes" (CIM 98-39 / J. Cdn. Pet. Tech. 39(6),
2000). OnePetro or the Petroleum Society archive. Drop it in books/ and
it builds the same day, the same way Sagar-Doty-Schmidt and Ansari did.
Blocked on source — sand-control completions¶
Not implemented: wire-wrapped screen and slotted-liner completion pressure
drop. Both books in books/ discuss sand control conceptually (frac-pack,
gravel sizing, proppant conductivity) but print no completion pressure-drop
model for either. Implementing them would be from memory, which is the one
thing this engine does not do.
To unblock: Golan & Whitson, Well Performance (2nd ed.) Ch. 4, or
Furui, Zhu & Hill on screen completions. Either in books/ and both models
build the same day.
Related finding: gravel_pack_skin carries no citation¶
It is the ONLY model in the engine without a source line. The equation
s_g = k h L_g / (k_g n pi r_p^2)
is the standard gravel-pack skin and its behaviour is correct — skin rises with tunnel length, falls with shot density and gravel permeability, and the existing tests exercise it — but the citation needs verifying against a source before any number from it goes into a customer-facing report. Everything else in this engine can name where it came from; this cannot, and that inconsistency is worth closing rather than leaving implicit.
Resolved: compositional traverse across the phase boundary¶
The known limitation recorded when CompositionalFluid landed — a traverse
crossing the saturation pressure would not converge — is fixed, and the
test that pinned it has been inverted rather than deleted.
Cause. A depth step straddling the phase boundary chases a fixed point that moves underneath it: properties jump at the boundary, so the iteration oscillates.
Fix: adaptive sub-stepping. A step that fails to converge is retried in
halves, up to max_substeps (default 16). This does not make the iteration
cleverer — it makes the discontinuity smaller relative to the step, until it
falls inside one sub-step and the rest are smooth. It is why this works
where more damping does not: damping slows every segment to solve one,
sub-stepping pays only where the trouble is.
Evidence it is correct, not merely convergent — the answer is step-size independent through the boundary:
| outer step | BHP (psia) |
|---|---|
| 150 m | 1864.9 |
| 75 m | 1868.4 |
| 40 m | 1866.0 |
0.2% across a 4x refinement. (A 300 m step gives 1824.7 and that is not a sub-stepping failure — ten steps for a 3000 m well is too coarse to resolve the column at all.)
Black oil is untouched: the demo well still returns Pwf 4594.24 psia,
bit-identical, in 82 ms. Sub-stepping only triggers on non-convergence, so
it costs nothing where it is not needed. max_substeps=1 restores the old
behaviour and a test asserts it, so the mechanism's effect is attributable
rather than assumed.
Also: the EOS flash is now memoised on 1 kPa / 0.05 K bins. A traverse asks for thousands of flashes at nearly-identical states and an EOS flash is three orders of magnitude dearer than a correlation. Boundary-crossing traverse 125 s -> 40 s, same answers to the decimal. The bins are 1e-4 of a reservoir pressure, far below any correlation's own accuracy, and rounding also makes properties piecewise-constant near convergence, which helps the iteration terminate rather than hurting it.
Gas-lift operations Quicklook — behavior-tested¶
Phase 3 implements source-backed screening behavior from Takacs, Gas Lift Manual (2005), Chapter 10, printed pp. 421-434:
- recent, synchronized, calibrated, stabilized well-test evidence gate;
- coincident pressure-gradient and local-temperature changes at valve depth;
- distinct between-valve tubing-leak candidates;
- synchronized surface patterns for backpressure, supply instability, injection restriction, high-gas/low-CHP, and heading/cycling;
- combined findings that retain alternatives and missing confirmation; and
- daily Phase 1 optimisation replay mapping with coverage-aware lookback accounting.
Validation grade: behavior-tested, not field-confirmed. Synthetic fixtures exercise every implemented pattern, restraint behavior, missing-data gate, unit boundary, and opportunity-accounting identity. No diagnostic threshold was fitted to competitor output. Confirmed field diagnoses require independent survey, production-log, pressure-test, equipment-response, or operating-record evidence. API RP 11V5 procedures are not claimed because the standard is not in the local source library. RP 19G5 (2019) is also now withdrawn; the current consolidated target is API RP 19GLHB R2025 with Addenda 1-3. Commercial conformance work should use that licensed package and treat 11V5/19G5 as historical or contract-specific crosswalks. The Phase 3 report defines the required field package, independent ground truth, frozen-threshold holdout process, and acceptance metrics.
Tooling closure on 2026-08-11: the full 785-test suite passes, including the 52 persistence/auth/project tests against a suite-isolated temporary SQLite database. Ruff 0.12.7 passes all Phase 3 files.
ESP v1 - published-example and analytically validated¶
Phase 4 uses vendor-neutral, user-entered pump curves. Takacs, Electrical Submersible Pumps Manual, Section 2.2.2.6 Eqs. 2.17-2.19 and Example 2.5 validate speed scaling: the published 3,500-rpm point scales to 1,000 bpd, 16 ft, and 18.5 hp at 2,917 rpm with efficiency unchanged.
Production Engineering Chapter 14 Example 14.1 validates hydraulic sizing: approximately 2,263 ft reference-liquid head, 37.7 required stages, and 38 selected stages. Exact SI hydrostatics give about 3,005 ft minimum setting depth versus the source's 2,997 ft using its rounded 0.433 psi/ft freshwater gradient; the source-rounding difference is documented and not tuned away.
Cable voltage drop and three-phase power loss are analytically anchored to Takacs Eqs. 3.18-3.19 and 5.17-5.18. Gauge head back-calculation is anchored to the pressure/head identity. Free-gas, viscosity, solids, temperature, clearance, and motor-loading limits are caller/manufacturer inputs. No vendor catalogue or correction curve is copied, reconstructed, or silently assumed.
Closure evidence: 77 focused tests, 815 full-suite tests, and Ruff on all Phase 4 files. Validation does not constitute manufacturer certification or field-confirmed equipment diagnosis.
Static flow assurance - source-available Phase 5 scope¶
API RP 14E Section 2.5(a), Eq. 2.14 anchors the erosional-velocity screen. Tests reproduce the published field-unit identity, exercise actual/allowable velocity status, and require an explicit factor basis. Solids-producing service is unavailable unless the caller supplies a documented solids-service factor; the engine does not invent a universal sand derating.
Turner et al. (1969) Eq. 6 uses the field-adjusted coefficient 1.912; Coleman et al. (1991) Eq. 3 deliberately removes Turner's 20% field increase and uses 1.593 for the reported low-pressure population. Tests keep those identities distinct and reproduce the Lea/Nickens/Wells worked example: approximately 11.30 ft/s for Coleman and 13.56 ft/s for Turner. Velocity margin, mass-conserving actual-to-standard critical-rate conversion, and Coleman's low-pressure applicability warning are also covered.
Belfroid et al. (2008) Eq. 1 is implemented in its primary-paper SI form with
inclination measured from horizontal. A separately named
belfroid_api19glhb method implements the different field-unit identity in
API RP 19GLHB Addendum 2 Eq. 66; the two are not silently conflated. Nagoo et
al. (2018) Eq. 1 is implemented directly in SI and requires local inclination
from vertical plus hydraulic diameter. An ordered profile calculation applies
the selected method along measured depth and reports the controlling node.
Tests cover exact equation identity, angle conventions, geometry requirements,
the Addendum 2 Figure 18.1 directional behavior, and profile ordering. These
remain screening criteria, not field-confirmed unloading diagnoses.
Regime-depth output groups only contiguous labels already returned by the VLP traverse. Ordering, unknown labels, and single-node bands are behavior-tested; no new flow-pattern correlation, transient slug model, or severe-slugging prediction is claimed.
Refreshed closure evidence: 859 full-suite tests, 65 versioned API operations, 116 focused artificial-lift/flow-assurance tests, and Ruff pass on all Phase 5 and touched boundary files. The API RP 19GLHB R2025 base package is now present and its software-scope disposition is complete. This does not replace the manufacturer, facility, calibrated-field, or independent diagnostic evidence required for an installation or blanket conformance claim.
Artificial-lift and flow-assurance release proof¶
Phase 6 validates delivery and integration contracts rather than adding a new engineering model. After the base-package extension, all 116 focused artificial-lift/flow-assurance cases and the complete 859-test repository suite pass. The generated OpenAPI schema contains 22 Sowah-track operations within 65 versioned operations. Scoped Ruff passes for the complete lift/assurance implementation, its API and unit boundaries, release smoke harness, and associated tests.
The production topology was built and exercised at /app against an isolated
SQLite database. All 15 smoke screens rendered without console errors, failed
requests, or HTTP errors. This proves application wiring and browser behavior;
it does not upgrade behavior-tested engineering models to field-confirmed or
manufacturer-certified status.
Integration is not yet proven against John's newer main line. The local
origin/main reference has 54 commits not in this branch, and a read-only
merge audit predicts conflicts in shared API/schema/unit boundaries. Those
files require deliberate reconciliation followed by the same complete proof
sequence. No merge or result claim may silently select one side wholesale.
API RP 19GLHB R2025 software disposition¶
The complete base handbook and Addenda 1-3 are now available. The applicable
continuous-lift, operations, automation/allocation, deliquification, and
high-pressure boundaries are dispositioned in
art_lift_fa/api-rp-19glhb-disposition.md.
The Section 12 unloading-readiness screen behavior-tests the 1 bbl/min liquid displacement limit, approximately 2%-25% initial injection-rate guidance, controlled ramp, adjustable injection control, casing/tubing pressure monitoring, and surface-capacity evidence. The Section 11 valve cross-check reproduces Table 11.12 valve 1 at approximately 1,139 psig test-rack opening pressure.
Refreshed evidence: 859 complete-suite tests, 22 Sowah-track API operations, 65 versioned API operations, and scoped Ruff pass. This is a software-scope validation statement. Manufacturer API 19G1/19G2 records, facilities, calibrated field procedures, independent diagnostic labels, and out-of-scope intermittent/dual/high-pressure designs are not certified by these tests.