ESP Design & Optimisation¶
Size an electrical submersible pump from the curve supplied by the engineer and check whether the complete assembly can operate and fit.
Vendor-neutral input¶
MINT does not invent a pump catalogue. Enter the rate, head per stage, power, and efficiency points from the applicable vendor datasheet, plus its reference speed and density.
Design outputs¶
- interpolated duty point;
- required head and selected whole-stage count;
- efficiency and shaft power;
- off-design speed/frequency behavior through affinity laws;
- motor, cable, voltage-drop, current, and drive considerations;
- intake-gauge pressure back-calculation where supplied; and
- casing clearance, assembly OD, temperature, and free-gas envelope.
MINT does not extrapolate outside the entered pump curve. Clearance and temperature failures are hard installation gates, not advisory warnings.
The well schematic places the pump, intake or gas separator, protector, motor, cable, completion restrictions, and perforations at their entered depths.