Gas-Lift Operations & Diagnostics¶
Turn operating data into a defensible view of where the well is injecting and what action is available.
Inputs¶
- synchronized oil, water, produced-gas, and injection-gas rates;
- casing, tubing, and bottomhole pressures where available;
- pressure and temperature surveys;
- installed valve depths and completion geometry; and
- time-series data for trend and lookback analysis.
Data quality first¶
MINT checks timestamps, missing channels, pressure consistency, survey depth, and other prerequisites before diagnosis. A weak input cannot become a strong diagnosis merely because an algorithm returned a label.
Diagnostic outputs¶
- likely injection depth;
- multipointing indications;
- possible tubing, casing, or valve leakage;
- unloading and operating-valve issues;
- surface pressure/rate trends;
- controlled-unloading readiness;
- evidence supporting each finding; and
- opportunity lookback across historical days.
Findings are located on the same depth schematic used for design. Suspected faults remain diagnoses, not equipment-certification claims, until confirmed by appropriate field evidence.